Savoy G3 amplifier input sensitivity switch settings.

Savoy G3 amplifier input sensitivity switch settings.

The Savoy G3 theater amplifier provides sensitivity settings so you can level match the input sensitivity of the Savoy G3 with the output voltage of your theater processor.

The back panel input sensitivity switch has three options: A, B, & C. The input voltages required to drive a single channel to full output power (240 watts @ 8 Ohms) at the different switch settings are: A = 1.2 volts, B = 1.6 volts, C = 2.2 volts. Power output into an 8 Ohm load with a 1 volt input: A = 190 watts/39.1 volts, B = 110 watts/29.4 volts, C = 60 watts/21.5 volts.

The default sensitivity switch setting is option C as it provides the greatest protection and noise reduction for most home theater applications. The B setting is the THX standard, and setting A would be used if your preamp/processor has higher output voltages.

Savoy G3 manual is attached.
    • Related Articles

    • Input Configuration settings: X / XR series processors and receivers

      The Input Configuration settings in the X series processors and XR series receivers allow you to optimize audio settings for each input depending on the type of source device you have connected to an input. To access the setup menu go to the front ...
    • Microphone Input Setup: CM Series 70 volt amplifiers.

      The CM Series 70 Volt amplifiers can be setup for use with a microphone for paging applications. The Channel 1-2 analog input connector is used for the microphone connection. Connect the three wires of your XLR microphone – hot to “+”, neutral to ...
    • Renaming Dante Inputs on your AudioControl Dante Amplifier

      Dante Input Names On AudioControl's Dante-enabled amplifiers, like the M4800D, M6800D, and the CM 70V Dante amps, the inputs shared between amplifiers will automatically display their chosen name when you click Look for Devices. For example, on your ...
    • Is the Dirac on/off command global, or per input?

      The Dirac EQ on/off command is per input basis. You can disengage the Dirac EQ by pressing the “audio” button on the HTR-2 remote that came with your AVR or M9. It is NOT a global command. For example, if you turned on Dirac for your Satellite box ...
    • How to use the 12 volt trigger options on an Architect amplifier.

      Architect amplifiers have both local zone 12 volt trigger connections and Master 12 volt trigger connections. The Local zone connection is a 3.5mm TS input connector. The Master trigger connection is either the 3-pin block connector or the two 3.5mm ...