On the CM2-750, CM3-750, CM4-750, and their Dante-enabled counterparts, the zones can be turned on & off via IP command, 12V trigger, or Signal Sense.
Check the following to make sure it works:
- Turn the zones ON.
- Turn global power ON, either via trigger or web UI global power button.
- Check that signal sense is active int he Amplifier settings.
Setting up Signal Sense
Local Zones
The zones need to be turned on in order for them to turn on via signal sense.
The zones have 3 statuses:
When the zone is OFF, it will not turn on when signal is received. Click the button in the web UI, send an IP command, or send +12VDC to the local trigger to turn it on.
When the zone power icon in the web UI is Orange, the zone is in standby awaiting signal.
When the zone power icon is Green, the zone is ON, and it has turned on when signal was sensed. After 2 minutes without signal, the zone will go back into standby, and the power icon will revert to orange.
Remember, if the zone power icon is not highlighted, the zone is off and it will not turn on with signal sense.
Global Power
In order for Signal Sense to work, the main power for the amp needs to be turned on. That means that either the +12V Trigger Jumper needs to be connected, or the Global Power button at the top of the page needs to be turned on (highlighted Green).
Master trigger with jumper between +12V & Trigger Input
Global power ON
The CM amplifiers come with the +12V Trigger jumper already installed.
If you have the trigger jumper connected, the global power does not need to be on. Conversely, if global power is on, the +12V Trigger jumper does not need to be connected.
Amplifier Settings
From factory, these amplifiers should come with signal sense already active.
To
confirm, open the global settings by clicking the gear icon, and check
the Amplifier settings panel at the top of the list. You should see it
say "SENSE ON", and when you open the Amplifier settings, the Signal
Sense button will be highlighted orange.
If it says "SENSE OFF" and the button is not highlighted, click the Signal Sense button to activate it.
Additional Assistance
If you still have questions, reach out to our tech support team!
Tel. 425-775-8461
Related Articles
How to setup SDS – Signal Detection Switching – on Director and CM-70 volt matrix DSP amplifiers.
The AudioControl Director Matrix series and CM 70 volt Matrix series amplifiers have a feature called SDS which stands for Signal Detection Switching. SDS allows you to connect the audio output of a doorbell system, home automation system, or a voice ...
Does Signal Sense work with Dante Inputs?
Yes! If signal sense is On on your Dante amplifier and the zones are set to a Dante input, as soon as signal is sensed on that input the connected zones will turn on and output audio. Signal sensing does not actively switch inputs, so if a zone is ...
How to bridge amp channels on the CM-series 70 Volt amplifiers
The CM2-750, CM3-750, and CM4-750 all have channels that can be bridged together to deliver more power to your speakers. If you need to provide power to 100V speakers, you need to use bridging to ensure you get enough power to your speakers. On the ...
How to use Input Sensitivty on a Director, CM, or RS amplifier
Input Sensitivity controls allow you to make the inputs on your amplifier more or less sensitive to incoming signal from audio sources. To change the input sensitivity, navigate to the amp's web interface, open the Global Settings by clicking the ...
How to use the 12 volt trigger options on an Architect amplifier.
Architect amplifiers have both local zone 12 volt trigger connections and Master 12 volt trigger connections. The Local zone connection is a 3.5mm TS input connector. The Master trigger connection is either the 3-pin block connector or the two 3.5mm ...